Postoperatively, all patients underwent repeat CT imaging within

Postoperatively, all patients underwent repeat CT imaging within six months of surgery, biplanar radiographs at two weeks, six weeks, three months, six months, and one year. All studies were reviewed independently by a neuroradiologist and two orthopedic spine surgeons.

Results. Fifty implants (38 L4-5, 12 L3-4) were placed in 38 patients who completed follow-up and were included in final analysis. Three IPS designs were included (34 Medtronic X-STOP titanium, ON-01910 in vivo 8 X-STOP PEEK, 8 Lanx Aspen). Postoperative CT revealed 11 nondisplaced spinous process fractures in 11 patients (28.9% of patients, 22% of levels). Five fractures were associated with mild to moderate lumbar back pain and six

fractures were asymptomatic. No patient reported a traumatic incident. No fracture was identifiable on plain radiographs. One fracture displaced during follow-up evaluation. Three patients underwent IPS removal and laminectomy. Three fractures healed by CT in one year. Overall, patients with fractures tended toward poorer outcomes by Zurich Claudication Questionnaire (ZCQ) (28.5% vs. 34.8% improvement

in symptom find more severity, P = 0.496; 21.4% vs. 30.7% improvement in physical function, P = 0.199) and tended toward lower satisfaction rates (50% vs. 73.7%, P = 0.24) at one year compared to patients without fracture.

Conclusion. Interspinous process spacer surgery appears associated with a higher rate of early postoperative spinous process fracture than previously reported. In all cases, in this series, plain radiographs were inadequate to identify fractures because all fractures were initially minimal PF-6463922 order or nondisplaced, many patients were osteopenic,

and the metallic wings of the devices often obscured fractures. Moreover, in most patients, fractures were associated with mild or no acute localized pain. This study suggests that unrecognized spinous process fracture may be responsible for a significant number of patients who experience unsatisfactory outcome after IPS surgery. CT imaging is required to identify the vast majority of such fractures.”
“Background: A recent postlicensure study from El Salvador showed that the monovalent rotavirus vaccine conferred 76% protection against rotavirus hospitalizations. We further examined the impact of rotavirus vaccination on the national burden of childhood diarrhea to help assess the total public health benefits of vaccination.

Methods: We compared all-cause diarrhea and rotavirus-specific hospitalization rates during prevaccine year 2006, with postvaccine years 2008 and 2009 in children <5 years of age from 7 sentinel surveillance hospitals. We also compared annual rates of diarrhea-related healthcare events during prevaccine years 2005 and 2006 with postvaccine years 2008 and 2009 to examine the national burden of healthcare utilization for all-cause diarrhea.