067) was similar in groups 1 and 2. The mean coronal obliquity of the femoral tunnel was significantly lower in group 1 than in group 2 (42.5 degrees 6.1 degrees vs 49.3 degrees +/- 7.2 degrees, respectively; P = .001), but the mean sagittal obliquity was similar between the 2 groups (41.9 degrees +/- 6.1 degrees vs 43.3 degrees +/- 5.4 degrees, respectively; P = .303). The mean area of the tunnel orifice was significantly greater in group 1 than in group 2 (11.6 +/- 1.4 x 9.2 +/- 1.6 mm vs 10.3 +/-
1.1 x 9.1 +/- 1.4 mm, respectively; P = .013). Conclusion: The modified transtibial technique for SB ACL reconstruction showed good clinical results and anatomic placement of the femoral tunnel, similar with those of the AM portal technique.”
“Technological advancement in hardware and software development in myocardial perfusion imaging (MPI) leads to the shortening of acquisition time and reduction of the radiation burden to patients. We compared semiquantitative selleckchem perfusion results and functional parameters of the left ventricle between new dedicated cardiac system with astigmatic collimators called IQ-SPECT (Siemens Medical Solutions, USA) and conventional single photon emission tomography (SPET) system equipped with standard low energy high resolution collimators. A group of randomly selected 81 patients underwent consecutively the MPI procedure on IQ-SPECT and on conventional SPET systen, PD0325901 both without
attenuation correction. The summed scores and the values of the functional parameters of the left ventricle: ejection fraction (EF), end-systolic and end-diastolic volumes (ESV, EDV) received from the automatic analysis software were compared and statistically analyzed. Our results showed that summed scores values were significantly higher for the IQ-SPECT system in comparison to the conventional one.
Calculated EF were significantly lower for IQ-SPECT, whereas evaluated left ventricular volumes (LVV) were significantly higher for this system. In conclusion, we recorded significant differences in automatically calculated semiquantitative perfusion and functional parameters when compared uncorrected studies obtained by the IQ-SPECT with the conventional SPET system.”
“Purpose: To describe spontaneous blink kinematics in Graves’ upper eyelid retraction (UER).\n\nMethods: The magnetic search coil technique was used Combretastatin A4 molecular weight to record spontaneous blinks of 15 healthy subjects (aged 23-56 years, 15 eyelids) and 15 patients with Graves’ UER (aged 22-62 years, 15 eyelids) during a 5-min period of video observation, and the signals were digitized at 200 Hz (12 bits). Overall, a total of 2,798 blinks were recorded for the controls and 1,860 for the patients. The distance between pupil center and upper eyelid margin in the primary position of gaze (MRD) was measured with the Image J software.\n\nResults: The blinking rate of patients was lower than that of control subjects, with a mean (+/-SEM) blinking rate (blinks/min) of 13.0 +/- 1.